mirror of
https://github.com/opencontainers/runtime-spec.git
synced 2026-02-05 09:45:57 +01:00
Merge pull request #1076 from Creatone/creatone/mon-support
config-linux: Add Intel RDT CMT and MBM Linux support
This commit is contained in:
@@ -554,6 +554,13 @@ The following rules on parameters MUST be applied:
|
||||
|
||||
* If `closID` is set, and neither of `l3CacheSchema` and `memBwSchema` are set, runtime MUST check if corresponding pre-configured directory `closID` is present in mounted `resctrl`. If such pre-configured directory `closID` exists, runtime MUST assign container to this `closID` and [generate an error](runtime.md#errors) if directory does not exist.
|
||||
|
||||
* **`enableCMT`** *(boolean, OPTIONAL)* - specifies if Intel RDT CMT should be enabled:
|
||||
* CMT (Cache Monitoring Technology) supports monitoring of the last-level cache (LLC) occupancy
|
||||
for the container.
|
||||
|
||||
* **`enableMBM`** *(boolean, OPTIONAL)* - specifies if Intel RDT MBM should be enabled:
|
||||
* MBM (Memory Bandwidth Monitoring) supports monitoring of total and local memory bandwidth
|
||||
for the container.
|
||||
|
||||
### Example
|
||||
|
||||
|
||||
@@ -259,6 +259,12 @@
|
||||
"memBwSchema": {
|
||||
"type": "string",
|
||||
"pattern": "^MB:[^\\n]*$"
|
||||
},
|
||||
"enableCMT": {
|
||||
"type": "boolean"
|
||||
},
|
||||
"enableMBM": {
|
||||
"type": "boolean"
|
||||
}
|
||||
}
|
||||
},
|
||||
|
||||
@@ -180,7 +180,7 @@ type Linux struct {
|
||||
// MountLabel specifies the selinux context for the mounts in the container.
|
||||
MountLabel string `json:"mountLabel,omitempty"`
|
||||
// IntelRdt contains Intel Resource Director Technology (RDT) information for
|
||||
// handling resource constraints (e.g., L3 cache, memory bandwidth) for the container
|
||||
// handling resource constraints and monitoring metrics (e.g., L3 cache, memory bandwidth) for the container
|
||||
IntelRdt *LinuxIntelRdt `json:"intelRdt,omitempty"`
|
||||
// Personality contains configuration for the Linux personality syscall
|
||||
Personality *LinuxPersonality `json:"personality,omitempty"`
|
||||
@@ -685,8 +685,9 @@ type LinuxSyscall struct {
|
||||
Args []LinuxSeccompArg `json:"args,omitempty"`
|
||||
}
|
||||
|
||||
// LinuxIntelRdt has container runtime resource constraints for Intel RDT
|
||||
// CAT and MBA features which introduced in Linux 4.10 and 4.12 kernel
|
||||
// LinuxIntelRdt has container runtime resource constraints for Intel RDT CAT and MBA
|
||||
// features and flags enabling Intel RDT CMT and MBM features.
|
||||
// Intel RDT features are available in Linux 4.14 and newer kernel versions.
|
||||
type LinuxIntelRdt struct {
|
||||
// The identity for RDT Class of Service
|
||||
ClosID string `json:"closID,omitempty"`
|
||||
@@ -699,6 +700,14 @@ type LinuxIntelRdt struct {
|
||||
// The unit of memory bandwidth is specified in "percentages" by
|
||||
// default, and in "MBps" if MBA Software Controller is enabled.
|
||||
MemBwSchema string `json:"memBwSchema,omitempty"`
|
||||
|
||||
// EnableCMT is the flag to indicate if the Intel RDT CMT is enabled. CMT (Cache Monitoring Technology) supports monitoring of
|
||||
// the last-level cache (LLC) occupancy for the container.
|
||||
EnableCMT bool `json:"enableCMT,omitempty"`
|
||||
|
||||
// EnableMBM is the flag to indicate if the Intel RDT MBM is enabled. MBM (Memory Bandwidth Monitoring) supports monitoring of
|
||||
// total and local memory bandwidth for the container.
|
||||
EnableMBM bool `json:"enableMBM,omitempty"`
|
||||
}
|
||||
|
||||
// ZOS contains platform-specific configuration for z/OS based containers.
|
||||
|
||||