= Compute nodes that need to access an ignition endpoint
|
|
|
|
When compute nodes need a proxy to access the ignition endpoint, you must configure the proxy in the user-data stub that is configured on the compute node when it is created. For cases where machines need a proxy to access the ignition URL, the proxy configuration is included in the stub.
|
|
|
|
The stub resembles the following example:
|
|
|
|
[source,terminal]
|
|
---
|
|
{"ignition":{"config":{"merge":[{"httpHeaders":[{"name":"Authorization","value":"Bearer ..."},{"name":"TargetConfigVersionHash","value":"a4c1b0dd"}],"source":"https://ignition.controlplanehost.example.com/ignition","verification":{}}],"replace":{"verification":{}}},"proxy":{"httpProxy":"http://proxy.example.org:3128", "httpsProxy":"https://proxy.example.org:3129", "noProxy":"host.example.org"},"security":{"tls":{"certificateAuthorities":[{"source":"...","verification":{}}]}},"timeouts":{},"version":"3.2.0"},"passwd":{},"storage":{},"systemd":{}}
|
|
--- |